About This Item
- Full TextFull Text(subscription required)
- Pay-Per-View PurchasePay-Per-View
Purchase Options Explain
Share This Item
The AAPG/Datapages Combined Publications Database
AAPG Bulletin
Abstract
AAPG Bulletin, V.
DOI:10.1306/04180807079
Connectivity of fluvial point-bar deposits: An example from the Miocene Huesca fluvial fan, Ebro Basin, Spain
Marinus E. Donselaar,1 Irina Overeem2
1Department of Geotechnology, Delft University of Technology, Stevinweg 1, P.O. Box 5048, 2600 GA Delft, Netherlands; [email protected]
2Department of Geotechnology, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, Netherlands; present address: Institute of Arctic and Alpine Research, University of Colorado, Campus Box 450, Boulder, 80309-0450, Colorado; [email protected]
ABSTRACT
The Huesca fluvial fan (Miocene, Ebro Basin, Spain) contains a low-gradient, mixed-load fluvial system. A detailed outcrop study of its meandering river deposits shows that the preservation of elongate channel-floor sandstone ribbons is common and that these deposits create a continuous along-stream sand-to-sand connectivity between successive crescent-shaped sandy point-bar accumulations on both sides of the channel. The combined appearance of the sandstone resembles a string of beads consisting of a thin, sinuous ribbon with thick and wide protuberances on either side. The studied meandering river sandstone bodies are laterally amalgamated and vertically stacked with a net-to-gross (N/G) ratio of about 40%. They occur in 1–1.5-km (0.62–1-mi)-wide, northeast–southwest-oriented elongate meander belts occupying paleochannels. Beyond these belts, the sandstone is limited to isolated bodies with a very low N/G ratio.
A generic model of the string-of-beads geometry, based on the outcrop data analysis, showed a significant increase of bulk rock volume for the connected string of beads compared with the model of isolated point bars.
The outcrop results demonstrate the potential for channel-floor sandstone bodies to be preserved in a low-gradient, mixed-load fluvial system and their importance in connecting point-bar units in an along-stream direction. We recommend that fluvial reservoir architecture modeling programs include a function that allows the connectivity between channel-floor and point-bar architectural elements. This may greatly impact the estimated reservoir volumes and recovery factors in primary and secondary production as well as influence the sweep efficiency of enhanced recovery technologies.
Pay-Per-View Purchase Options
The article is available through a document delivery service. Explain these Purchase Options.
Watermarked PDF Document: $14 | |
Open PDF Document: $24 |
AAPG Member?
Please login with your Member username and password.
Members of AAPG receive access to the full AAPG Bulletin Archives as part of their membership. For more information, contact the AAPG Membership Department at [email protected].