About This Item

Share This Item

The AAPG/Datapages Combined Publications Database

AAPG Bulletin

Abstract

DOI: 10.1306/02252221037

Previous HitReservoirNext Hit Previous HitcharacterizationNext Hit and comparison of seismicity-Previous HitmonitoringNext Hit methods at West Seminole for CO2 utilization and storage

Shawn M. McCloskey,1 Paul F. Anderson,2 and Mohammad Mirzaei3

1Occidental, Houston, Texas; [email protected]
2Occidental, Houston, Texas; [email protected]
3Occidental, Houston, Texas; [email protected]

ABSTRACT

Transitioning to a low-carbon future is now one of the industry’s most important challenges, and one opportunity to reduce greenhouse gas emissions is through development of carbon capture utilization and storage projects. This paper describes the Previous HitreservoirNext Hit Previous HitcharacterizationNext Hit and seismic Previous HitmonitoringNext Hit for the West Seminole San Andres unit that is located in Gaines County, Texas, on the Central Basin platform within the Permian Basin. Outcrop analogues and detailed core descriptions were used to build a high-resolution, sequence stratigraphic framework to evaluate the viability of the site for carbon storage potential. Geologic Previous HitcharacterizationNext Hit consisting of core description, three-dimensional seismic interpretation, and well log correlation was performed on the Previous HitreservoirNext Hit interval to determine storage capacity. Hydraulic conductivity and breakthrough pressure were analyzed and calculated for the confining layers to estimate seal integrity. A review of historical seismicity from public databases reveals no past activity in the area. Installation of a surface seismic array and a downhole fiber optic cable provided independent tools for Previous HitmonitoringNext Hit seismicity at the site. The surface array’s modeled magnitude of completeness of better than local magnitude 0.7 exceeds the California Air Resources Board requirement to inform of the potential for a magnitude 2.7 or greater event. The results of the full site Previous HitcharacterizationTop demonstrate that the West Seminole San Andres unit has favorable storage capacity, a robust caprock seal, and a low risk of induced seismicity.

Pay-Per-View Purchase Options

The article is available through a document delivery service. Explain these Purchase Options.

Watermarked PDF Document: $14
Open PDF Document: $24

AAPG Member?

Please login with your Member username and password.

Members of AAPG receive access to the full AAPG Bulletin Archives as part of their membership. For more information, contact the AAPG Membership Department at [email protected].